Method steps for fixing an air conditioning wooden pallet in a piping system

According to the layout of the equipment room, nine points are selected in the ground position of the equipment room. At the nine points, the same height channel is used as the column, and the upper part of the column is connected by channel steel. The channel steel columns are also connected by channel steel to form a ring-shaped and grid fixed plane of the channel steel frame. Considering that if the air-conditioning wood pallet pipe is directly fixed on the channel plane, it will inevitably cause the ground floor of the basement equipment room. Larger vibration effects, so a channel member with the same plane shape as the channel connecting the columns is separately fabricated and placed completely on the upper channel plane of the column, in the middle of the two channel ring planes. A damping pad with strong damping effect is set, and then the pipe is fixed on the upper plane of the upper channel steel, and a vibration damping pad is arranged in the lower part of the air conditioning wooden pipe; then all the fixing parts originally fixed on the concrete ceiling are given Dismantled to achieve the separation of the pipe and the ceiling; so fixed, all the pipes are supported by the ring steel through the column.

The vibration of the air-conditioning wooden pallet from the pipeline is eliminated by the following steps: Since the damping pad is arranged between the pipeline and the channel surface, the vibration is first eliminated at this position; secondly, the two upper and lower annular grooves are identical in shape. The damping pad between the steel faces was eliminated in the second way; since the vibration damping measures were also set between the bottom of the channel steel column and the ground, the vibration from the air-conditioning wooden pallet was eliminated a third time; To ensure the effect of the scheme, the damping pad of the water pump and the chiller was replaced; through the above measures, the ground of the machine room and the ground floor of the first floor basically have no vibration feeling when the system is running, and the effect is very obvious. In addition, in order to eliminate noise pollution, the entire equipment room ceiling, surrounding walls, equipment doors and ventilation fan inlet and outlet are all silenced.

Openning Limitor

Openning Limitor,Door Opening Limiter,Door Limiter,Sliding Door Limiter

Zhejiang Tilanco Industry&Trade Group Co., Ltd , https://www.tilancogroup.com