Dial indicator force test operation method

Dial indicator force test operation method
Dial gauge tester structure:
The dial gauge tester uses the small-value force sensor to measure the high precision and good stability, and serves as the benchmark for measuring the force of the measuring instrument. Plus multi-functional fixtures to adapt to a variety of instruments to achieve a wide range of applications. Together with the base, adjustment device, etc., it constitutes a more ideal gauge dynamometer, the specific structure of which is shown in the figure.
Dial indicator calibration zero adjustment:
During the use of the instrument, if the power is turned on, it is found that the display does not return to zero or the “Err.on” phenomenon is displayed. You can press the power-on zero button first. If there is no effect, you can directly adjust the zero-position adjustable resistance (11) in the small hole at the back of the instrument to make it appear zero after power on.
SGSLC dial indicator tester picture
SGSLC dial indicator tester
Dial indicator tester self-school:
The SLC dial gauge calibration method is as follows:
Turn on the power switch, press the power-on clear button, make the display number zero, then take 1kg weight on the force plate, the display number should be in the range of 9.74N-9.86N (standard value is 9.80N), If it is not within this range, you can use the Rose batch to adjust the instrument's indication error adjustable resistor (11), so that the display number is in the range of 9.74N-9.86N, and the Zui is adjusted to the 9.80N standard value.
Dial indicator verification instrument error adjustment:
In the course of the use period verification, if the indication value is found to be out of tolerance. The indication error adjustable resistor (11) in the small hole at the back of the instrument can be adjusted to reach the indication error range.
SGSLC dial indicator tester picture
SGSLC dial indicator tester
Dial indicator tester specifications
Product number
( Model)
Range (N)
Graduation value
(N)
Dimensions
(mm)
weight
(KG)
SGSLC
0-15
0.01
230X220X310
10
Our company also sells: 3000KN electronic dynamometer Torque wrench tester Torque wrench Torque wrench price Rally gauge Torque wrench price Torque tester Electric batch torque tester Digital torque tester Digital pressure gauge Torque wrench