(UN2000A) Portable SpO2/ECG/NIBP/Rr/Temp Patient Monitor with Bluetooth
August 10 14:02:39, 2024
Model NO.: UN2000A
OEM: Support
Display: 5 Inch TFT-LCD
Bluetooth: Support
Gross Weight: 1kg
Touchscreen: Yes
Etco2: Optional
Bluetooth Printer: Optional
Net Weight: 655g
Dimension: 209X;104X47.5(mm)
Trademark: Union Medical
Transport Package: Carton
Origin: China
HS Code: 9018193010
Model NO.: UN2000A
OEM: Support
Display: 5 Inch TFT-LCD
Bluetooth: Support
Gross Weight: 1kg
Touchscreen: Yes
Etco2: Optional
Bluetooth Printer: Optional
Net Weight: 655g
Dimension: 209X;104X47.5(mm)
Trademark: Union Medical
Transport Package: Carton
Origin: China
HS Code: 9018193010
(UN2000A) Portable SPO2/ECG/NIBP/RR/TEMP Patient Monitor with Bluetooth
Model:UN2000A Waveform:ECG and SPO2 waveforms
Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data
Build-in rechargeable Li-battery, up to 15Â hours running time, support AC and DC power
Adjustable audible and visual alarms, and sensor off alarm
Long time monitoring and sleeping monitoring
Easy to carry, suitable for ambulance center, has the stand for fixing
ETCO2, FiCO2 and RR are optional
Priors Â
Storage and review data up to 3888groups via Trend Graph and Trend List
USB and Bluetooth data upload
Big font screen interface is easy to observe
Back light can be adjusted
Free advanced software are all standard on free
Optional Bluetooth printer to print the waveform and data out
Parameters
ECG
Input:5- lead ECG cable, standard AAMI cable connector Lead Selection:I,II,III, avR,avL,avF,C Gain Selection:×1,×2,×4,×8 Sweep Speed: 12.5, 25, and 50 mm/s Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB) Calibration Signal: 1mV square wave Protection: Against electrosurgical interference and defibrillation
Heart Rate
Measuring Range: 20 bpm~300 bpm Renew Time: 1 time per beat Accuracy: ±1 bpm Alarm Mode: Audible and visual alarm
Method: Oscillometric Mode: Manual, Auto, STAT Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min) Measuring Period in STAT Mode: 5 min Cuff Pressure Range:0 mmHg~300mmHg Pulse Rate Range:30 bpm~250bpm Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg Pressure Resolution: 1mmHg The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device.Â
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor Measuring Range: 0ºC~50ºC Accuracy: ±0.1ºC
EtCO2(Optional)
Measuring Range:  0~150mmHg Resolution: 1 mmHg Accuracy: ±2mmHg@< 5.0% CO2 Respiration Rate(Optional) Measuring Range: 0~120rpm Resolution: 1rpm Accuracy: ±1rpm
Printer (optional)
Type: Thermal micro-printer Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm Interface: Bluetooth wireless interface Recording Types: Real-time printing and review data printing Power Supply: Rechargeable battery 1700mAh~2000mAh.7.2V.  Charge(discharge) >=1000times. Charge time: 2hours Work Operation/relative humidity:0~55ºC/10~80%RH Storage Operation/relative humidity:-20~60ºC/10~90%RH
Payment
Shipping
Â
(UN2000A) Portable SPO2/ECG/NIBP/RR/TEMP Patient Monitor with Bluetooth
Model:UN2000A Waveform:ECG and SPO2 waveforms
Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data
Build-in rechargeable Li-battery, up to 15Â hours running time, support AC and DC power
Adjustable audible and visual alarms, and sensor off alarm
Long time monitoring and sleeping monitoring
Easy to carry, suitable for ambulance center, has the stand for fixing
ETCO2, FiCO2 and RR are optional
Priors Â
Storage and review data up to 3888groups via Trend Graph and Trend List
USB and Bluetooth data upload
Big font screen interface is easy to observe
Back light can be adjusted
Free advanced software are all standard on free
Optional Bluetooth printer to print the waveform and data out
Parameters
ECG
Input:5- lead ECG cable, standard AAMI cable connector Lead Selection:I,II,III, avR,avL,avF,C Gain Selection:×1,×2,×4,×8 Sweep Speed: 12.5, 25, and 50 mm/s Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB) Calibration Signal: 1mV square wave Protection: Against electrosurgical interference and defibrillation
Heart Rate
Measuring Range: 20 bpm~300 bpm Renew Time: 1 time per beat Accuracy: ±1 bpm Alarm Mode: Audible and visual alarm
Method: Oscillometric Mode: Manual, Auto, STAT Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min) Measuring Period in STAT Mode: 5 min Cuff Pressure Range:0 mmHg~300mmHg Pulse Rate Range:30 bpm~250bpm Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg Pressure Resolution: 1mmHg The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device.Â
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor Measuring Range: 0ºC~50ºC Accuracy: ±0.1ºC
EtCO2(Optional)
Measuring Range:  0~150mmHg Resolution: 1 mmHg Accuracy: ±2mmHg@< 5.0% CO2 Respiration Rate(Optional) Measuring Range: 0~120rpm Resolution: 1rpm Accuracy: ±1rpm
Printer (optional)
Type: Thermal micro-printer Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm Interface: Bluetooth wireless interface Recording Types: Real-time printing and review data printing Power Supply: Rechargeable battery 1700mAh~2000mAh.7.2V.  Charge(discharge) >=1000times. Charge time: 2hours Work Operation/relative humidity:0~55ºC/10~80%RH Storage Operation/relative humidity:-20~60ºC/10~90%RH