Ysbn-200 Medical Hospital Infant Newborn Neonatal Baby Body Warmer
August 11 09:01:00, 2024
Model NO.: Ysbn-200
Trademark: YSENMED
Transport Package: Wooden Case
Specification: 2120*900*450-750mm
Origin: China
Model NO.: Ysbn-200
Trademark: YSENMED
Transport Package: Wooden Case
Specification: 2120*900*450-750mm
Origin: China
YSBN-200 medical infant radiant warmer
Brief introduction: 1. Three modes of control: Manual, skin temperature and mattress temperature 2. Alloyed bracket, fastness 3. Microprocessor based servo controlled temperature system 4. Control panel displayed by VFD 5. Digital skin temperature sensor, the data is exact and stabilizability 6. High sensitivity and untouched detector to inspect mattress temperature 7. Alarm functions for safety include Power failure, temperature deviation Temperature probe failure, over temperature 8. APGAR timer to record therapy time 9. Observe light angle can be adjusted + 90º , and the brightness adjusted 10. Heater head can be adjusted + 90º Horizontally 11. Electric infant bed tilt angle is + 10º , transparent protector folded 12. Convenient X-ray cassette under infant bed 13. Electric height adjusted suit for operation 14. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long 15. Alarms are audible and visual 16. A second thermal cut-out function for more safety 17. Skin temperature sensor failure protect function avoid over temperature Standard configuration 1. Main body (including the radiant source, control system, infant bed, electric lift stand), I. V. Pole, skin sensor, mattress, one drawer, transparent protector, castors 2. Optional parts: Low pressure aspirator; Oxygen supply system, LED phototherapy unit.
Technical data: 1. Power supply: 110/220V 60/50Hz 2. Power input: ≤ 1000VA 3. Operating condition An ambient Temperature: 18° C-30° C An ambient Relative Humidity: 30%--75%RH Atmospheric Pressure: 700~1060 hPa An ambient Air Velocity <0.3m/s 4. Range of Skin Temperature control: 32° C~38° C 5. Temperature control accuracy: ≤ 0.5° C 6. Alarms functions: A. Over temperature: > 39° C B. A second thermal cut- out: 40° C C. Sensor alarm: Skin temperature sensor failure Mattress temperature sensor failure Room temperature sensor failure D. Power failure 7. Mattress temperature uniformity: <2° C 8. Skin temperature sensor accuracy: ≤ 0.3° C 9. Mattress temperature sensor accuracy: ≤ 0.4° C 10. Room temperature sensor accuracy: ≤ 0.3° C 11. Warm-up time: ≤ 30min 12. Height adjustable range: 0-20CM 13. Bed tilt angle: + 10° 14. APGAR timer range: ≤ 24h 15. Heater head horizontal: ± 90° 16. Mattress size: 76CM X 65CM 17. Distance from heater to mattress: 90CM 18. Whole unit size: 70CMX 110CMX 180CM (180-200CM) 19. Castor load: 1pc≤ 200kg 4pcs≤ 800kg
Transport and storage 1. Environment Temperature: -40° C~ +55° C 2. Environment Relative Humidity: ≤ 95% 3. Atmospheric Pressure: 500~1060hPa
Package: Each unit is packed one case Size: 114CMX 94CM X 104CM Gross weight: ≤ 190KG Yuesenmed provides various equipment for clinics. We guarantee high quality, reasonable prices and fast delivery. We are a company aiming to make one stop shopping for our customers.Â
We listed some hospital basic items for your reference as below:Â
One-stop shopping Hospital medical equipment
X ray room
X ray machine
Processor
X ray film
Cassette
Intensifying screen
Lead clothings(lead glove, lead glasses, Lead cap, lead apron, lead collar)
Ultrasound
B/w 2D ultrasound
2/3/4D color ultrasound
Laboratory room
Chemistry analyzer
Hematology analyzer
Microplate elisa reader
Microplate washer
Centrifuge
Pipette
Water bath
Urine analyzer
Operation room
Anesthesia machine
Ventilator
Operating lamp
Operation table
Pendant
Medical drill and saw
ECG
Patient monitor
Defibrillator
Infusion pump
Electrocoagulation
Oxygen generator
Electric suction device
Autoclave sterilizer
For more hospital medical equipment, please go to our homepage and search by catagories. Thanks for your interest!Â
YSBN-200 medical infant radiant warmer
Brief introduction: 1. Three modes of control: Manual, skin temperature and mattress temperature 2. Alloyed bracket, fastness 3. Microprocessor based servo controlled temperature system 4. Control panel displayed by VFD 5. Digital skin temperature sensor, the data is exact and stabilizability 6. High sensitivity and untouched detector to inspect mattress temperature 7. Alarm functions for safety include Power failure, temperature deviation Temperature probe failure, over temperature 8. APGAR timer to record therapy time 9. Observe light angle can be adjusted + 90º , and the brightness adjusted 10. Heater head can be adjusted + 90º Horizontally 11. Electric infant bed tilt angle is + 10º , transparent protector folded 12. Convenient X-ray cassette under infant bed 13. Electric height adjusted suit for operation 14. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long 15. Alarms are audible and visual 16. A second thermal cut-out function for more safety 17. Skin temperature sensor failure protect function avoid over temperature Standard configuration 1. Main body (including the radiant source, control system, infant bed, electric lift stand), I. V. Pole, skin sensor, mattress, one drawer, transparent protector, castors 2. Optional parts: Low pressure aspirator; Oxygen supply system, LED phototherapy unit.
Technical data: 1. Power supply: 110/220V 60/50Hz 2. Power input: ≤ 1000VA 3. Operating condition An ambient Temperature: 18° C-30° C An ambient Relative Humidity: 30%--75%RH Atmospheric Pressure: 700~1060 hPa An ambient Air Velocity <0.3m/s 4. Range of Skin Temperature control: 32° C~38° C 5. Temperature control accuracy: ≤ 0.5° C 6. Alarms functions: A. Over temperature: > 39° C B. A second thermal cut- out: 40° C C. Sensor alarm: Skin temperature sensor failure Mattress temperature sensor failure Room temperature sensor failure D. Power failure 7. Mattress temperature uniformity: <2° C 8. Skin temperature sensor accuracy: ≤ 0.3° C 9. Mattress temperature sensor accuracy: ≤ 0.4° C 10. Room temperature sensor accuracy: ≤ 0.3° C 11. Warm-up time: ≤ 30min 12. Height adjustable range: 0-20CM 13. Bed tilt angle: + 10° 14. APGAR timer range: ≤ 24h 15. Heater head horizontal: ± 90° 16. Mattress size: 76CM X 65CM 17. Distance from heater to mattress: 90CM 18. Whole unit size: 70CMX 110CMX 180CM (180-200CM) 19. Castor load: 1pc≤ 200kg 4pcs≤ 800kg
Transport and storage 1. Environment Temperature: -40° C~ +55° C 2. Environment Relative Humidity: ≤ 95% 3. Atmospheric Pressure: 500~1060hPa
Package: Each unit is packed one case Size: 114CMX 94CM X 104CM Gross weight: ≤ 190KG Yuesenmed provides various equipment for clinics. We guarantee high quality, reasonable prices and fast delivery. We are a company aiming to make one stop shopping for our customers.Â
We listed some hospital basic items for your reference as below:Â
One-stop shopping Hospital medical equipment
X ray room
X ray machine
Processor
X ray film
Cassette
Intensifying screen
Lead clothings(lead glove, lead glasses, Lead cap, lead apron, lead collar)
Ultrasound
B/w 2D ultrasound
2/3/4D color ultrasound
Laboratory room
Chemistry analyzer
Hematology analyzer
Microplate elisa reader
Microplate washer
Centrifuge
Pipette
Water bath
Urine analyzer
Operation room
Anesthesia machine
Ventilator
Operating lamp
Operation table
Pendant
Medical drill and saw
ECG
Patient monitor
Defibrillator
Infusion pump
Electrocoagulation
Oxygen generator
Electric suction device
Autoclave sterilizer
For more hospital medical equipment, please go to our homepage and search by catagories. Thanks for your interest!Â