2018 New Breathing Hand Held Compressor Nebulizer Kids
August 11 03:01:08, 2024
Model NO.: NBB04
Electrical Requirements: 110V/220VAC/50Hz/60Hz
Power Consumption: <=75W
Fuse: F1.6al250V
Classification: Class II Equipment, Type B Applied Part.
Weight: 1.5kg
Sound Pressure Level: <53 dB(a)
Trademark: HINOR
Transport Package: Cartons
Specification: 176mm(H) x160mm (W)x 115mm(D)
Origin: Shandong, China
HS Code: 90192000
Model NO.: NBB04
Electrical Requirements: 110V/220VAC/50Hz/60Hz
Power Consumption: <=75W
Fuse: F1.6al250V
Classification: Class II Equipment, Type B Applied Part.
Weight: 1.5kg
Sound Pressure Level: <53 dB(a)
Trademark: HINOR
Transport Package: Cartons
Specification: 176mm(H) x160mm (W)x 115mm(D)
Origin: Shandong, China
HS Code: 90192000
2018 new breathing  hand held compressor nebulizer treatment with nebulizer kits NBB04 Â
Description:
The NBB04 Nebulizer is a hand held compressor nebulizer for nebulizer treatment with kits,The NBB04 Nebulizer is intended for adult and pediatric patients consistent with the indications for the aerosol medication.
Specifications: Â
No.
Item
Rating
1
Electrical Requirements     Â
110V/220Vac/50Hz/60Hz
2
Power Consumption                                                        Â
≤75W
3
Dimensions
176mm(H) x160mm (W)x 115mm(D).
4
Fuse
F1.6AL250V
5
Classification
class II equipment, Type B applied part.
6.
Weight
1.5Kg
7
Sound Pressure Level
<53 dB(A)
8.
Maximum Pressure
205Kpa
9.
Operating Pressure                                                    Â
110KPa
10.
Liter Flow Range
<12 L/Min
11.
Operation Humidity&Temperature
5°C to 40°C  30%to95%RH
12.
Storage Humidity&Temperature
- 40°C to 70°C  10%to100%RH
How to cleaning the nebulizer:
NOTE: Clean the Nebulizer set after every use and at least once a day. Â Â Â Â Â Â Â The Nebulizer set is single use. 1. Turn the power off and unplug from the wall outlet. 2. Remove the tubing from the air inlet. 3. Disassemble mouthpiece, T-piece, nebulizer cap, chamber and baffle, and wash in hot water with dish washing soap. Rinse thoroughly. 4. Mix one part of white vinegar with three parts water in a clean container. Submerge mouthpiece. T-piece, nebulizer cap, chamber and baffle cap for one half hour. 5. Remove the components from the solution an let dry
Images:
More info
Â
FAQ
Q: We have design,can you produce? A: Yes,welcome! Customize package and OEM printing are available.
Q:What is delivery time? A:Usually 10 days.
Q: How to ensure the products' quality? A: Samples will be sent to you for test firstly; Each production stage will show you in time ; the product quality will be test and show you before delivery.
Q: How is your after sales? A: Generally 18 months guarantee. Any damage results from us, we will take responsibility to compensate the loss. " Customer" is the first.
Q: How can I get a sample? A: The Sample will be shipped out in 7 working days after we received your payment if no special requirements.
Q: Which payment way is workable? A: L/C T/T.
Q: Can I book an order if less than MOQ? A: Yes. Please tell us your quantity,and your detailed address, thenwe will work out the cost for you.Â
2018 new breathing  hand held compressor nebulizer treatment with nebulizer kits NBB04 Â
Description:
The NBB04 Nebulizer is a hand held compressor nebulizer for nebulizer treatment with kits,The NBB04 Nebulizer is intended for adult and pediatric patients consistent with the indications for the aerosol medication.
Specifications: Â
No.
Item
Rating
1
Electrical Requirements     Â
110V/220Vac/50Hz/60Hz
2
Power Consumption                                                        Â
≤75W
3
Dimensions
176mm(H) x160mm (W)x 115mm(D).
4
Fuse
F1.6AL250V
5
Classification
class II equipment, Type B applied part.
6.
Weight
1.5Kg
7
Sound Pressure Level
<53 dB(A)
8.
Maximum Pressure
205Kpa
9.
Operating Pressure                                                    Â
110KPa
10.
Liter Flow Range
<12 L/Min
11.
Operation Humidity&Temperature
5°C to 40°C  30%to95%RH
12.
Storage Humidity&Temperature
- 40°C to 70°C  10%to100%RH
How to cleaning the nebulizer:
NOTE: Clean the Nebulizer set after every use and at least once a day. Â Â Â Â Â Â Â The Nebulizer set is single use. 1. Turn the power off and unplug from the wall outlet. 2. Remove the tubing from the air inlet. 3. Disassemble mouthpiece, T-piece, nebulizer cap, chamber and baffle, and wash in hot water with dish washing soap. Rinse thoroughly. 4. Mix one part of white vinegar with three parts water in a clean container. Submerge mouthpiece. T-piece, nebulizer cap, chamber and baffle cap for one half hour. 5. Remove the components from the solution an let dry
Images:
More info
Â
FAQ
Q: We have design,can you produce? A: Yes,welcome! Customize package and OEM printing are available.
Q:What is delivery time? A:Usually 10 days.
Q: How to ensure the products' quality? A: Samples will be sent to you for test firstly; Each production stage will show you in time ; the product quality will be test and show you before delivery.
Q: How is your after sales? A: Generally 18 months guarantee. Any damage results from us, we will take responsibility to compensate the loss. " Customer" is the first.
Q: How can I get a sample? A: The Sample will be shipped out in 7 working days after we received your payment if no special requirements.
Q: Which payment way is workable? A: L/C T/T.
Q: Can I book an order if less than MOQ? A: Yes. Please tell us your quantity,and your detailed address, thenwe will work out the cost for you.Â