10ml Tthree Part, Disposable Syringe (Lure Lock) with Needle

Model NO.: YD1097
Group: Adult
Needle: With Needle
Syringe Use: High Precision Experiments
Disinfection: Disinfection
Medical Device Regulatory Type: Type 3
Medical Devices Reg./Record No.: Ssyjxzz-2001-0249
Size: 1-100ml
Trademark: IU
Transport Package: 1PC Per Bag, 100PCS/Box
Specification: CE certificate and ISO 9001: 2000/13485
Origin: CHINA
HS Code: 90183900
Model NO.: YD1097
Group: Adult
Needle: With Needle
Syringe Use: High Precision Experiments
Disinfection: Disinfection
Medical Device Regulatory Type: Type 3
Medical Devices Reg./Record No.: Ssyjxzz-2001-0249
Size: 1-100ml
Trademark: IU
Transport Package: 1PC Per Bag, 100PCS/Box
Specification: CE certificate and ISO 9001: 2000/13485
Origin: CHINA
HS Code: 90183900
Disposable syringe lure lock or lure slip

Disposable syringe for hypodermic, intramuscular and intravenous injection.

1. Sterilized by EO gas, non-toxic, non-pyrogenic, single use only.

2. Luer Slip or Luer Lock.

3. Sufficiently transparent barrel allows easy measurement of the volume contained in the syringe and detection of air bubble.

4. Graduated scale on the barrel is easy to read. Graduation is printed by indelible ink.

5. The plunger fits the inside of barrel very well to allow for free and smooth movement.

6. Material for barrel and plunger: Medical grade PP(polypropylene).

7. Material for gasket: Natural latex / Synthetic rubber(latex free).

8. With or without needle.

9. Individual pack: Blister pack / Polybag.

10. Available size: 1mL, 2mL(2.5mL), 3mL, 5mL, 10mL, 20mL, 30mL, 50mL, 60mL. 100ml

11. Standard: IS13485 and CE 0123
Name of Sample Disposable Syringe With Needle LOT 20120204
Type 10ml   22G*11/4 MFG  DATE 20120204
Quantity 1084800PCS Serial LOT 20120204
Testing Standards GB15810-2001and Invoices NO.YD-T111228 EXP DATE 20170204
Testing Items Standard Requirement And Standard Term And Conditions Test Result
Biological Properties Sterility Should be Sterile Eligible
Pyrogen No pyrogen  Eligible
Chemical Properties Readily Oxidizable Substance Comparing with the contrast liquid with same batch and same volume, the consumption deference of potassium permanganate 0.002mol/L≤0.5Ml  unit: mL (5.11.3) 0.35
pH Comparing with contrast liquid in the same batch, not more than 1.0PH (5.11.2) 0.42
Ethylene Oxide Rudimental quantity ≤10mg/g  unit: mg/g (5.11.4) 0.19
Physics
Properties
Outer Conical Point Meet regulations in GB 1962/T;No water drop;
Without obvious continuous bubbles formed;Can't be
separated;No stress cracks occurred.
Eligible
Permissible Tolerance Of Capacity ≥half of nominal volume: ±4%(mL) (5.10.3) Eligible
Device Sealing Character No water drops;Without blow-by, the piston and core bar can't be separated Eligible
Printing Of Measuring Scale Side Needle Style:Print at the opposite side of cone Eligible
Center Needle Style:Print at random side of minor axis of cylinder
Ruler Requirement 1mL≥57mm;2-3mL≥27mm;5mL≥36mm ;10mL≥44mm;20mL≥52mm;   unit: mm 57.8
Sliding Performance Max starting tensile force ≤25N;Max. Thrusting force: not more than(2.0XF) or (F+1.5N), choose the maximum value;Min. Thrusting force: not less than(2.0X F) or (F-1.5N), choose the maximum value;Average thrusting force: ≤10N; Eligible
Rubber Piston Without rubber thread, scrap, foreign bodies;
When piston engaging with outer cylinder, the core bar can be move resulting from self weight
Eligible
Appearance Requirement Clean, without impurity ;
No raw edge, burr, plastic flow etc flaws
Eligible
Residual Quantity 1-3ml ≤ 0.07mL; 5ml ≤ 0.075mL;10ml ≤ 0.10mL ;
20ml ≤ 0.15mL;    Unit: mL
0.089
Individual Package Meets the contract requirement Eligible
Cone Requirement ≥1.2mm, Eligible
Graduation Line Of Measuring Scale Coincide with piston baseline; the deviation is not more than 1/4 min. Division;Should be 1/2 of major division lines Eligible
Testing Results Eligible
Disposable syringe lure lock or lure slip

Disposable syringe for hypodermic, intramuscular and intravenous injection.

1. Sterilized by EO gas, non-toxic, non-pyrogenic, single use only.

2. Luer Slip or Luer Lock.

3. Sufficiently transparent barrel allows easy measurement of the volume contained in the syringe and detection of air bubble.

4. Graduated scale on the barrel is easy to read. Graduation is printed by indelible ink.

5. The plunger fits the inside of barrel very well to allow for free and smooth movement.

6. Material for barrel and plunger: Medical grade PP(polypropylene).

7. Material for gasket: Natural latex / Synthetic rubber(latex free).

8. With or without needle.

9. Individual pack: Blister pack / Polybag.

10. Available size: 1mL, 2mL(2.5mL), 3mL, 5mL, 10mL, 20mL, 30mL, 50mL, 60mL. 100ml

11. Standard: IS13485 and CE 0123
Name of Sample Disposable Syringe With Needle LOT 20120204
Type 10ml   22G*11/4 MFG  DATE 20120204
Quantity 1084800PCS Serial LOT 20120204
Testing Standards GB15810-2001and Invoices NO.YD-T111228 EXP DATE 20170204
Testing Items Standard Requirement And Standard Term And Conditions Test Result
Biological Properties Sterility Should be Sterile Eligible
Pyrogen No pyrogen  Eligible
Chemical Properties Readily Oxidizable Substance Comparing with the contrast liquid with same batch and same volume, the consumption deference of potassium permanganate 0.002mol/L≤0.5Ml  unit: mL (5.11.3) 0.35
pH Comparing with contrast liquid in the same batch, not more than 1.0PH (5.11.2) 0.42
Ethylene Oxide Rudimental quantity ≤10mg/g  unit: mg/g (5.11.4) 0.19
Physics
Properties
Outer Conical Point Meet regulations in GB 1962/T;No water drop;
Without obvious continuous bubbles formed;Can't be
separated;No stress cracks occurred.
Eligible
Permissible Tolerance Of Capacity ≥half of nominal volume: ±4%(mL) (5.10.3) Eligible
Device Sealing Character No water drops;Without blow-by, the piston and core bar can't be separated Eligible
Printing Of Measuring Scale Side Needle Style:Print at the opposite side of cone Eligible
Center Needle Style:Print at random side of minor axis of cylinder
Ruler Requirement 1mL≥57mm;2-3mL≥27mm;5mL≥36mm ;10mL≥44mm;20mL≥52mm;   unit: mm 57.8
Sliding Performance Max starting tensile force ≤25N;Max. Thrusting force: not more than(2.0XF) or (F+1.5N), choose the maximum value;Min. Thrusting force: not less than(2.0X F) or (F-1.5N), choose the maximum value;Average thrusting force: ≤10N; Eligible
Rubber Piston Without rubber thread, scrap, foreign bodies;
When piston engaging with outer cylinder, the core bar can be move resulting from self weight
Eligible
Appearance Requirement Clean, without impurity ;
No raw edge, burr, plastic flow etc flaws
Eligible
Residual Quantity 1-3ml ≤ 0.07mL; 5ml ≤ 0.075mL;10ml ≤ 0.10mL ;
20ml ≤ 0.15mL;    Unit: mL
0.089
Individual Package Meets the contract requirement Eligible
Cone Requirement ≥1.2mm, Eligible
Graduation Line Of Measuring Scale Coincide with piston baseline; the deviation is not more than 1/4 min. Division;Should be 1/2 of major division lines Eligible
Testing Results Eligible

Low Pesticide Goji Berry, also called EU standard Goji Berry. Ningxia goji berry enjoys a great fame around the global due to its high quality standard; meanwhile, it is the only protected product of geographical identity in China, goji berry has a great popularity describes as "goji berry of the world is in China, goji berry of China is in Ningxia and Ningxia's goji berry is the best".

1.Type Genus: Multi-branched deciduous shrub of Solanaceae Lycium

2.Another name: wolfberry, red berry, red pendant, blood berry, eye-brighten berry, Tzi-fruit, hoof berry, milk berry, immortality grass, sky-essence grass, wolfberry

3.Biology Character: illumination preferable, saline-alkali tolerance, fertilizer tolerance, drought-resistant, water stain should be sustained.

4.Medicinal Parts: goji berry/ goji berry leaves, goji berry roots. low pesticide goji

Low Pesticide Goji Berry

Low Pesticide Goji Berry,Low Pesticide Goji,Low Pesticide Residue Wolfberry,Low Pesticide Dried Goji Berry

Ningxia Bairuiyuan International Trading Co.,Ltd , http://www.cngoji.com